<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>40677</ErrorNumber>
<ErrorFamily>Media Handler</ErrorFamily>
<ErrorMessage>
MDH: The leading edge clamp was expected closed, but was found to be open
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Magnus_VLF</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The firmware was expecting the leading edge clamps to be closed, but they were found
open.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Select RESUME
</text></DescriptionText>
</OperatorAction>
<Availability>
<DescriptionText><text>
This error is reported.
</text></DescriptionText>
</Availability>
<Cause>
Faulty sensor -
The sensor may have been damaged.
</Cause>
<Cause>
Faulty plumbing -
The solenoid, cylinder, or the air supply may be faulty.
</Cause>
<LastModified>
07-Aug-2002
</LastModified>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:29 2008 PST
</Updated>
<Links>
</Links>
</Error>